Titre: Electric fields applied in the ultrafiltration process
Auteur(s): Lounici, Hakim
Mots-clés: Ultrafiltration; Electro-ultrafiltration; Fouling electric field; Bovine serum albumin
Date de publication: mar-2001
Editeur: universite de bouira
Référence bibliographique: Elsevier Science
Résumé: Concentration polarisation is one of the main limitations of permeate flux through membranes. A conventional crossflow ultrafillration apparatus was modified by the inclusion of electrodes which permitted an electric field to be produced across the ultrafiltration membrane. This study examined the impact of operating parameters on fouling including flux, velocity, transmembrane pressure and electric field. Studies of the EF-UR process with bovine serum albumin (BSA) in the range of 1-5 g/1 demonstrated a 25-50% increase of the flux permeate compared to the case of 0 electric field.
URI/URL: http://dspace.univ-bouira.dz:8080/jspui/handle/123456789/6588
Collection(s) :Articles

Fichier(s) constituant ce document :
Fichier Description TailleFormat 
Electric fields applied in the ultrafiltration process.pdf35,73 kBAdobe PDFVoir/Ouvrir